Var, and pf control modes underfrequency compensation voltshertz line drop compensation autotracking between operating modes and between redundant cgcm units automatic transfer to a backup cgcm unit in redundant systems generator paralleling with reactive droop compensation or crosscurrent reactive differential. The woodward psg governor is a pressure compensated, speed droop or isochronous governor for controlling the speed of small diesel, gas, and gasoline engines, or small steam or industrial gas turbines. This is because some functions of the group controller bear resemblance to woodwards ls5 device. What is the difference between a droop and an isochronous. Product manual 04042 revision l, 220 original instructions tg and tg17 governors tg611 and tg61117 governors installation and operation manual.
The isochronous mode is used for constant speed of the controlled prime mover with. The governor is used to control engines or turbines driving alternators, dc generators, pumps, or compressors. During restoration, it may be required to modify droop settings to provide adequate frequency response to support the load restoration process. Apr 30, 2006 in a nutshell, isochronous speed control refers to the prime mover governor speed control mode that controls the frequency speed of an ac generator alternator and droop speed control refers to the prime mover governor speed control mode that allows multiple ac generators alternators to be operated in parallel with each other to power large electrical loads, or to share load. Typically, black start units have the ability to operate in isochronous mode which is 0% droop and 0 mhzrpm dead band. Droop is used to guarantee a fall of frequency according to the load. The isochronous mode is used for constant speed of the controlled prime mover as long as it is able to provide the load. Rami rajamaki load sharing communication between different. Pgg governor woodward, kral, dynalco, dcl, ingersoll. It allows the engine to run at lower speed when the load increases and at rated speed at no load droop is expressed as a percentage of the original speed setting from no load to full load.
Isoch mode, the 2301dst controls plantunit frequency control by maintaining turbine speed. The isochronous mode is used for constant speed of the controlled prime mover as long as it is able to provide power to satisfy the load. Even though 5% or even 10% droop may be used on a large grid, the mode of operation is such. It is especially useful in parallel generatorset applications where alternator frequencies must be matched, or the governor operated in droop mode for load distribution. The woodward pgg governor is used for controlling speed or power output of engines where remote speedsetting capabilities with droop are required. If the generator is connected to the utility bus while in droop mode, the unit speed will be determined entirely by the bus frequency. Governor droop is a governor function which reduces the governor reference speed as fuel position load increases. The egb10p, p, or 35p governoractuator is used with woodward analog or digital electronic controls that provide a proportional 20160 ma signal to control dual fuel, diesel, and gasoline. With 21 kpa 3 psi minimum and 690 kpa 100 psi maximum control air pressure. All generator sets in the system except one are operated in the droop mode. Droop speed control is a control mode used for ac electrical power generators, whereby the.
Isochronous load sharing principles for an islanded system. Speed trim allows manual adjustment of output level with an external 10 k. View and download woodward 2301d installation and operation manual online. In auxiliary control mode it can control generator power, exhaust pressure, inlet pressure, plant import export level etc.
Dslc2 digital synchronizer and load control woodward. Droop load sharing left and isochronous load sharing. However, no responsibility is assumed by woodward governor company unless otherwise expressly. Generator operation modes there are three modes of operation for generators. Page 11 speed droop the 3161 governor is an isochronous governor with the ability to operate in the droop mode by the adjustment of the internal droop. The woodward 2301dst is a microprocessor based control with integral application software designed for singlevalve steam.
The electronics must be able to function in droop mode for units that are. I attached some literature from woodward that may assist with your understanding. The one unit not in droop is operated in the isochronous mode. Even though 5% or even 10% droop may be used on a large grid, the mode of operation is such that the system frequency will never see that much variation.
Woodward 505 installation and operation manual pdf. Droop mode allows operation of a generator on an infinite bus or in parallel with other engine generator units using hydromechanical governors. The 2301a provides control in either the isochronous or droop mode. The control can be set to operate within one of the following rated speed ranges. Many applications easily accept some speed droop which means a less costly and complex governor can be used, even if the genset will be paralleled with other units. It can be seen that, two faults are required in any part of the control system before the governor is forced into droop mode. While many caterpillar engines utilize advanced electronic control systems, with integrated engine speed governing capabilities, there are many caterpillar engines, both gas and diesel, that require the use of separate engine speed governing systems.
Droop mode is selected when either the droop switch or the auxiliary circuit breaker is open. Droop mode reduces speed by the system load as a percentage of full load. Single prime mover operation two or more prime movers controlled by woodward governor company load sharing control systems on an isolated bus. This provides a stable working point for each load in case of parallel operation. Generator breaker and tie breaker contacts are configured to change the governor from speed control mode to auxiliary mode or vise versa.
Based on droop control limitations, we will study techniques to improve its performance, and compare it with the crosscurrent compensation method. The amount of droop for a given setting depends on the magnetic pickup frequency and noload to fullload actuator shaft rotation. Front panel indications unit healthy status indication, speed setpoint mode indications. Introduction the combination generator control module cgcm unit is a microprocessorbased control and protection device.
Governing fundamentals and power management otherpower. The main difference between droop and isochronous control modes lies in their relationship to frequency. Compatible with optional woodward spma synchronizer. For the automatic voltage regulator and the reactive power something similar happens. For example, if you have a generator that can supply a maximum of 100 kva output. The droop mode is used for speed control as a function of load with. Comparison between isochronous control and droop control for speed regulation in parallel generators. In this mode the 505 internal overspeed trip will be changed to be just an alarm and the 505 will allow the speed to continue.
Missing member alarm is active gcb feedback mismatch alarm is active tiebreaker feedback mismatch alarm is active when tiebreaker connected the discrete input di 04 terminal 71 lsm speed control with droop is active. Read this entire manual and all other publications pertaining to the work to be. This is because some functions of the group controller bear resemblance to woodward s ls5 device. Isochronous load sharing principles for an islanded system with steam and gas turbine generators krishnanjan gubba ravikumar schweitzer engineering laboratories, inc. In the voltage control or droop mode, the avr is regulated by a droop characteristic, which is shown in the following drawing. View and download woodward dslc installation and operation manual online. In the droop speed control mode the speed will decrease by a fixed percentage when the generator is loaded from noload to full load. Manual 26641 2301e digital control woodward v warnings and notices important definitions this is the safety alert symbol. The ls module switches its own isochronous speed and voltage control into droop mode, when.
Speed droop and power generation application note 02 4 woodward the droop curve droop is a straightline function, with a certain speed reference for every fuel position. Digital load sharing and speed controls for engines. Isochronous load shar ing with other dslc 2 equipped sets. The 2301a speed control provides control in the isochronous mode with droop available through an externally wired potentiometer. Woodward 505 governor controlling operation askpowerplant. Droop operation is obtained by setting the droop potentiometer. Droop switch the external droop switch is to be wired in series with the auxiliary circuit. A governor tuned with speed droop will open the control valve a specified. Adjustable droop permits load division and balancing among parallel. Woodward 3161 governor installation and operation manual. It is acceptable to have a black start unit with zero droop. Dec 04, 2017 lecture on purpose of droop in governors by v r venkatesan, himt, chennai. Many gas turbines manufactured by general electric afford the operator two choices.
Singleengine operation two or more engines controlled by woodward load sharing control systems on an isolated bus base loading against an infinite bus with the load controlled by an automatic. Speed droop and power generation application note 02 woodward governor company reserves the right to update any portion of this publication at any time. It works by controlling the rate of power produced by the prime mover according to the grid. In such installations it is common to operate the governor in droop mode with external control of speed, and therefore load, being exercised by the power management network. The full authority speed control is compatible with woodward spma. Sync input compatible with optional woodward spma synchronizer. Droop switch the external droop switch is to be wired in series with the auxiliary circuit breaker contact. The woodward 2301a full authority speed control sets the speed or load of a diesel engine, gas engine, steam turbine, or gas turbine according to the demand of a process or a computer control signal. Load sharing module remains in the droop mode even when the circuit breaker. In the droop mode the 2301dst controls generator load. Normally, a droop governor lowers the speed reference from 3 to 5 percent of the reference speed over the full range of the governor output.
View and download woodward 505 installation and operation manual online. What is the difference between droop and isochronous operation. Outputs load signal dc signal proportional to total real current sensed by the load sharing module. It is commonly used as the speed control mode of the governor of a prime mover driving a synchronous generator connected to an electrical grid. Title load sharing communication between different engine generator controllers year 2015 language english. There is often a selector switch or operator interface screen allowing the operator to choose either governing mode. In the isochronous speed control mode the speed will return to the original. Mar 18, 2018 the woodward psg governor is a pressure compensated, speeddroop or isochronous governor for controlling the speed of small diesel, gas, and gasoline engines, or small steam or industrial gas turbines. The 2301a provides control in either isochronous or droop mode. In a nutshell, isochronous speed control refers to the prime mover governor speed control mode that controls the frequency speed of an ac generator alternator and droop speed control refers to the prime mover governor speed control mode that allows multiple ac generators alternators to be operated in parallel with each other to power large electrical loads, or to share load. A droop p oten im etr s ti gf 10 o c lk w iv ab u 4% dr, no d to. Woodward 723 plus applications manual pdf download.
Isochronous mode leaves speed fixed, and the load is picked up by control of load, typically running into one bus with much. Isochronous mode droop isochronous load sharing on an isolated bus droop isochronous combines the first two modes. Woodward governor company reserves the right to update any portion of this publication at any time. In isochronous mode, generators maintain a constant frequency, whereas droop mode allows for changes in frequency in response to changes in load. Title load sharing communication between different engine generator controllers year 2015 language english pages 62 name of supervisor juha nieminen new diesel, gas and dualfuel power plants have new engine controllers and voltage regulators which control the load sharing. The woodward psg governor is a speed droop governor for controlling speed of small diesel, gas, and gasoline engines, or small steam or industrial gas turbines, isochronously or with droop. Pdf design of an electronic governor for a diesel generator. Droop control is provided when parallelbus operation is required. See also, the woodward 505 lst manual page describing the speed droop deadband. Isochronous mode droopisochronous load sharing on an isolated bus droopisochronous combines the first two modes.
Control of synchronous generators with droop and cross. Each operation mode requires specific turbine fuel and generator excitation controls. Isochronous is also used when load sharing with a woodward load sensor. Control with isochronous loadsharing control in island mode. Woodward dslc installation and operation manual pdf download. Typically, black start units have the ability to operate in isochronous mode which is 0% droop. The design of an electronic governor to change the fuel valve of a diesel generator and the algorithm to control the speed is presented in this paper. Jun 30, 2015 in this video we discuss how a proportional control dependent on frequency and their variation with active p and reactive p powers can setup generators, inverters and manage a microgrid to.
Manual 02007 dslc digital synchronizer and load control figure 52. The unit provides isochronous operation, with droop control available through an externallywired potentiometer. Woodward 2301a load sharing and speed control features ul and csa listed isochronous or droop speed control isochronous load sharing idle and rated speed setting linear idletorated speed ramp, decel ramp available start fuel limit wide dynamic adjustment range failed speed sensor detector eu directive compliant application the load sharing and speed control is. The woodward 505 lst modbus speed droop deadband values are not configurable in either the configuration program mode or the service mode. Woodward 505 governor has over speed set point and mechanical over speed test. The cgcm unit is designed to integrate with a logix family programmable controller to provide generator control, protection and synchronization functions. Read this entire manual and all other publications pertaining to the work. In the isochronous speed control mode the speed will return to the original speed setpoint after a load has been applied or rejected. Isochronous means that the governer keep always the same frequency. Woodward 505 installation and operation manual pdf download. The difference between isochronous and droop control modes. What is the difference between isochronous and droop. View and download woodward 3161 governor installation and operation manual online.
This mode is active when the 2digit value being displayed is blinking. The isochronous mode is used for constant engine speed with. Information provided by woodward governor company is believed to be correct and reliable. Droop speed control is a control mode used for ac electrical power generators, whereby the power output of a generator reduces as the line frequency increases.
242 868 1096 1326 196 723 965 1360 412 85 249 901 726 202 478 1150 1336 374 954 579 817 46 220 1188 441 759 939 856 90 1015 1149 1089 1085 2 1068 310 677 143